HomeStore

Philips EBS 118 230 SH - Micropower Electronic ballast for TL/PL-S

Product image 1

Philips EBS 118 230 SH - Micropower Electronic ballast for TL/PL-S

Philips EBS 118 230 SH - Micropower Electronic ballast for TL/PL-S

Philips EBS 118 230 SH Electronic Ballast for UV & Fluorescent Lamps (4W–20W)

Philips EBS 118 230 SH Electronic Ballast – Technical Specifications

Parameter Specification
Product Name Philips EBS 118 230 SH Electronic Ballast
Ballast Type High-Frequency Electronic Ballast
Lamp Type UV & Fluorescent Lamps
Number of Lamps Single Lamp Operation
Compatible UV Lamps TUV 4W, 6W, 8W, 11W, 15W, 16W, 20W
Compatible TL Lamps TL 6W–18W
Compatible PL Lamps PL-S, PL-T, PL-C (7W–24W)
Rated Ballast-Lamp Power 18 W
Input Voltage 220–240 V AC
Input Frequency 50–60 Hz
Operating Frequency ≥ 42 kHz
Start Method Warm Start Ignition
Ignition Time ≤ 1 Second
Power Factor 1.0
Power Loss 3.5 W
Crest Factor (Max) 1.85
Energy Savings Up to 25% vs. Electromagnetic Ballasts
Automatic Restart Yes
Noise Level Inaudible
Input / Output Terminals WAGO 251 Universal Connectors
Wire Cross Section 0.50 – 1.50 mm²
Wire Strip Length 9–10 mm
Wiring Type Automatic & Manual (ALF & ADS)
Ambient Temperature (ta) 0 °C to +40 °C
Max Case Temperature (tc) 75 °C
Storage Temperature –40 °C to +85 °C
Emergency Operation Support Yes
Battery Voltage (Ignition) 198–254 V
Battery Voltage (Operation) 176–254 V
Housing Design Compact Square Housing
Weight 0.040 kg
Compliance Standards IEC 61347-2-3, IEC 61547

Typical Applications

UV Water/Air Systems, Labs, Medical, Industrial UV


The Philips EBS 118 230 SH is a compact, high-frequency electronic ballast (choke) designed for reliable and energy-efficient operation of single UV and fluorescent lamps. Engineered by Philips for professional applications, this ballast ensures long lamp life, stable ignition, and reduced power consumption, making it ideal for continuous-operation environments.

Compatible UV & Fluorescent Lamps

This ballast is suitable for operating one lamp from the following range:

  • Philips TUV UV lamps: 4W, 6W, 8W, 11W, 15W, 16W, 20W

  • TL lamps: 6–18 W

  • PL lamps: PL-S, PL-T, PL-C (7–24 W)

Key Benefits

  • Up to 25% energy savings compared to electromagnetic ballasts

  • Extended lamp lifetime, especially in long burning hour applications (IEC cycle)

  • Warm start ignition for reduced electrode wear

  • Compact and lightweight design for flexible installation

  • Automatic restart after power interruption

  • Silent operation with inaudible hum and noise

Electrical & Operating Specifications

  • Input Voltage: 220–240 V AC

  • Input Frequency: 50–60 Hz

  • Operating Frequency: ≥ 42 kHz

  • Rated Ballast-Lamp Power: 18 W

  • Power Factor: 1.0

  • Power Loss: 3.5 W

  • Crest Factor (Max): 1.85

  • Ignition Time: ≤ 1 second

  • Warm Start Ignition Method

Wiring & Installation

  • Input & Output Terminals: WAGO 251 universal connectors

  • Wire Cross Section: 0.50 – 1.50 mm²

  • Wire Strip Length: 9–10 mm

  • Suitable for automatic and manual wiring (ALF & ADS)

Temperature & Environmental Ratings

  • Ambient Temperature: 0 °C to +40 °C

  • Case Temperature (Max): 75 °C

  • Storage Temperature: –40 °C to +85 °C

  • Humidity & Safety Compliance: IEC 61347-2-3

  • EMC Immunity: IEC 61547

Emergency Operation Support

  • Battery Voltage (Lamp Ignition): 198–254 V

  • Battery Voltage (Lamp Operation): 176–254 V

Design & Build

  • Housing: Square, compact design

  • Weight: Only 0.040 kg

  • Noise Level: Inaudible

Applications

  • UV water and air disinfection systems

  • Laboratory and medical equipment

  • Industrial UV systems

  • Commercial and residential fluorescent lighting

  • Continuous-operation lighting installations

$2.37
Philips EBS 118 230 SH - Micropower Electronic ballast for TL/PL-S
$2.37

Product Information

Shipping & Returns

Description

Philips EBS 118 230 SH Electronic Ballast for UV & Fluorescent Lamps (4W–20W)

Philips EBS 118 230 SH Electronic Ballast – Technical Specifications

Parameter Specification
Product Name Philips EBS 118 230 SH Electronic Ballast
Ballast Type High-Frequency Electronic Ballast
Lamp Type UV & Fluorescent Lamps
Number of Lamps Single Lamp Operation
Compatible UV Lamps TUV 4W, 6W, 8W, 11W, 15W, 16W, 20W
Compatible TL Lamps TL 6W–18W
Compatible PL Lamps PL-S, PL-T, PL-C (7W–24W)
Rated Ballast-Lamp Power 18 W
Input Voltage 220–240 V AC
Input Frequency 50–60 Hz
Operating Frequency ≥ 42 kHz
Start Method Warm Start Ignition
Ignition Time ≤ 1 Second
Power Factor 1.0
Power Loss 3.5 W
Crest Factor (Max) 1.85
Energy Savings Up to 25% vs. Electromagnetic Ballasts
Automatic Restart Yes
Noise Level Inaudible
Input / Output Terminals WAGO 251 Universal Connectors
Wire Cross Section 0.50 – 1.50 mm²
Wire Strip Length 9–10 mm
Wiring Type Automatic & Manual (ALF & ADS)
Ambient Temperature (ta) 0 °C to +40 °C
Max Case Temperature (tc) 75 °C
Storage Temperature –40 °C to +85 °C
Emergency Operation Support Yes
Battery Voltage (Ignition) 198–254 V
Battery Voltage (Operation) 176–254 V
Housing Design Compact Square Housing
Weight 0.040 kg
Compliance Standards IEC 61347-2-3, IEC 61547

Typical Applications

UV Water/Air Systems, Labs, Medical, Industrial UV


The Philips EBS 118 230 SH is a compact, high-frequency electronic ballast (choke) designed for reliable and energy-efficient operation of single UV and fluorescent lamps. Engineered by Philips for professional applications, this ballast ensures long lamp life, stable ignition, and reduced power consumption, making it ideal for continuous-operation environments.

Compatible UV & Fluorescent Lamps

This ballast is suitable for operating one lamp from the following range:

  • Philips TUV UV lamps: 4W, 6W, 8W, 11W, 15W, 16W, 20W

  • TL lamps: 6–18 W

  • PL lamps: PL-S, PL-T, PL-C (7–24 W)

Key Benefits

  • Up to 25% energy savings compared to electromagnetic ballasts

  • Extended lamp lifetime, especially in long burning hour applications (IEC cycle)

  • Warm start ignition for reduced electrode wear

  • Compact and lightweight design for flexible installation

  • Automatic restart after power interruption

  • Silent operation with inaudible hum and noise

Electrical & Operating Specifications

  • Input Voltage: 220–240 V AC

  • Input Frequency: 50–60 Hz

  • Operating Frequency: ≥ 42 kHz

  • Rated Ballast-Lamp Power: 18 W

  • Power Factor: 1.0

  • Power Loss: 3.5 W

  • Crest Factor (Max): 1.85

  • Ignition Time: ≤ 1 second

  • Warm Start Ignition Method

Wiring & Installation

  • Input & Output Terminals: WAGO 251 universal connectors

  • Wire Cross Section: 0.50 – 1.50 mm²

  • Wire Strip Length: 9–10 mm

  • Suitable for automatic and manual wiring (ALF & ADS)

Temperature & Environmental Ratings

  • Ambient Temperature: 0 °C to +40 °C

  • Case Temperature (Max): 75 °C

  • Storage Temperature: –40 °C to +85 °C

  • Humidity & Safety Compliance: IEC 61347-2-3

  • EMC Immunity: IEC 61547

Emergency Operation Support

  • Battery Voltage (Lamp Ignition): 198–254 V

  • Battery Voltage (Lamp Operation): 176–254 V

Design & Build

  • Housing: Square, compact design

  • Weight: Only 0.040 kg

  • Noise Level: Inaudible

Applications

  • UV water and air disinfection systems

  • Laboratory and medical equipment

  • Industrial UV systems

  • Commercial and residential fluorescent lighting

  • Continuous-operation lighting installations